Basic circuits
For more information visit: www.EatonElectrical.comMN05013003E 185
Table 24: Cycle pulse on rising edge
Cycle pulse on falling edge
You can create a cycle pulse on a falling edge if you use the
appropriate coil function.
This is very useful for count pulses, jump pulses.
Table 25: Cycle pulse on falling edge
I1
Status of Q1
cycle n
Status of Q1
cycle n + 1
0 0 0
1
1 0
0
0 0
I1-------èQ1
S1 make contact at I1
I1
Status of Q1
cycle n
Status of Q1
cycle n + 1
1 0 0
0
1 0
1
0 0
EZ500_700.book Page 185 Tuesday, May 3, 2005 5:15 PM
Page view 188
1 2 ... 184 185 186 187 188 189 190 191 192 193 194 ... 299 300