Year time switch
For more information visit: www.EatonElectrical.comMN05013003E 175
Example : Selecting public holidays
The year time switch Y4 is required to switch on at 00:00 on
day 25.12 of each year and switch off at 23:59 on day 26.12
of each year. “Christmas program”
Example: Selecting a time range
The year time switch Y1 is required to switch on at 00:00 on
day 02.05 of each year and switch off at 23:59 on day 31.10
of each year. “Open air season”
Example: Overlapping ranges
The year time switch Y1 channel C switches on at 00:00 on
day 3 of months 5, 6, 7, 8, 9, 10 and remains on until 23:59 on
day 25 of these months.
The year time switch Y1 channel D switches on at 00:00 on
day 2 of the months 6, 7, 8, 9, 10, 11, 12 and remains on until
23:59 on day 17 of these months.
Circuit diagram display Parameter settings for the
year time switch Y4
Circuit diagram display Parameter settings for the
year time switch Y1
Y4-------ÄQ1 Y4 A +
ON 25.12.--
OFF 26.12.--
Y1-------ÄQ1 Y1 A +
ON 02.05.--
OFF --.--.--
Y1 B +
ON --.--.--
OFF 31.10.--
EZ500_700.book Page 175 Tuesday, May 3, 2005 5:15 PM