Wiring with EZ
MN05013003E146
Parameter display in RUN mode:
Value range of the operating hours counter
The operating hours counter counts in the range from 0 hours
to way over 100 years.
Accuracy of the operating hours counter
The operating hours counter counts in seconds. When the
device is switched off, up to 999 ms can be lost.
Function of the operating hours counter function block
When the coil of the O operating hours counter is set to 1, the
counter increments its actual value by 1 (basic pulse: 1
second).
If the actual value of the operating hours counter reaches the
setpoint of S, the contact O... switches for as long as the
actual value is greater than or equal to the setpoint.
The actual value is kept stored in the device until the Reset
coil RO... is triggered. The actual value is then set to zero.
Set time in hours
Actual time in hours
# Contact has not switched.
â Contact has switched.
O1 +
S 001000
# O:000309
EZ500_700.book Page 146 Tuesday, May 3, 2005 5:15 PM