Wiring with EZ
MN05013003E92
Representation in EZ:
•Markers M, N:
èM1 to èM16, èN1 to èN16
Jumps: è:1 to è:8
Rising edge evaluation (cycle pulse) È
This function is used if the coil is only meant to switch on a
rising edge. With a change in the coil state from 0 to 1, the coil
switches its make contacts to the 1 state for one cycle.
Figure 43: Signal diagram of cycle pulse with rising edge
Representation in EZ:
•Markers M, N:
ÈM1 to ÈM16, ÈN1 to ÈN16
Jumps: È:1 to È:8
J
Physical outputs should not be used as a cycle pulse is
generated.
on
on
J
Physical outputs should not be used as a cycle pulse is
generated.