XSwitch to Entry mode and move the cursor over the contact
name.
XPress ALT. The make contact will change to a break
contact.
XPress OK 2
× to confirm the change.
Figure 39: Changing contact I3 from make to break
Creating and modifying connections
Switch contacts and relay coils are connected with the wiring
arrow in Connect mode. EZ displays the cursor in this mode
as an arrow.
XUse
úíÍÚ to move the cursor onto the contact field or
coil field from which you wish to create a connection.
XPress ALT to switch to Connect mode.
XUse
úí to move the diagonal arrow between the contact
fields and coil fields and ÍÚ to move between rungs.
XPress ALT to leave Connect mode.
EZ will leave the mode automatically when you move the
diagonal arrow onto a contact field or coil field which has
already been assigned.
2 ×
I2u------ÄQ4
I3k
I2u------ÄQ4
i3k
I2u------ÄQ4
i3kê
l
J
Do not position the cursor on the first contact field. At this
position the ALT button has a different function (Insert
rung).
J
In a rung, EZ automatically connects switch contacts and
the connection to the relay coil if there are no empty fields
in-between.