Menu Information
9000X AF Drives MN04001004E—May 2011 www.eaton.com 45
Operate Menu (M8)
The Operate Menu provides an easy-to-use method of
viewing key numerical Monitoring Menu items. Some
applications also support the setting of reference values in
this menu. The items displayed vary by application. The table
below is an example for the standard application.
Operate Menu Items—Standard Application Example
The menu is navigated by using the left and right arrow
buttons. If a reference level is available for setting, the up
and down arrow buttons adjust the value. To exit the
Operate Menu to access the other menus, depress the
ENTER button for 2 seconds. While in the other menus, if
there is no keypad activity, the display will return to the
Operate Menu after 30 seconds. The figure below illustrates
the Operate Menu button function.
Operate Menu Navigation
Code Signal Name Unit Description
O.1 Output frequency Hz Output frequency
O.2 Freqreference Hz Frequency reference
O.3 Motor speed rpm Calculated motor speed
O.4 Motor current A Measured motor current
O.5 Motor torque % Calculated torque based on nominal motor torque
O.6 Motor power % Calculated power based on nominal motor power
O.7 Motor voltage V Calculated motor voltage
O.8 DC bus voltage V Measured DC bus voltage
O.9 Unit temperature °C Heatsink temperature
O.10 Motortemperature % Calculated motor temperature based on the motor nameplate
information and the calculated motor load
R1 Keypad reference Hz Keypad frequency reference setting
One Touch Operate Menu
Navigation
Freq Ref Up
Password ?
Freq Ref Down
Exit Operate Menu by navigating
to Programming display and
pressing ENTER button or simply
press ENTER button 2 seconds.
Acknowledgement password
Monitor Display
Navigation Left
Monitor Display
Navigation Right
Programming Menu
Note!
Up and Down arrows are defaulted to
frequency reference. Some applications
also support other references like
Torque or PID. The active reference is
selected with a parameter
.
Display will automatically
return to default Operate
Menu monitor display
after 30 sec. delay.
or time delay
M1 Parameters
M2 Keypad Control
M3 Active Faults
M4 Fault History
M5 System Menu
M6 Expander Boards
M7 Monitor
Return to Operate