Power Losses as Function of Switching Frequency
Raising the switching frequency of the drive, to reduce motor noise for example, inevitably
affects the power losses and cooling requirements as shown in Figure 2-7. It illustrates the
power loss for FR7 as a function of switching frequency. For more information, contact Eaton
or your local distributor.
Figure 2-7: Power Loss as a Function Frequency; SPI046 – 087, 480V
SPI061 400V
SPI087 400V
SPI061 500V SPI072 400V SPI072 500V
SPI087 500V
2,000,00
0,00
500,00
1000,00
1500,00
P[W]
2000,00
2500,00
4,00 6,00
Switching Frequency [kHz]
8,00 10,00 12,00