Instruction Manual IM01005019E - Rev.5
Effective November 2013
Eaton www.eaton.com 11
Eaton SPD Series
Surge Protective Device for Integrated Units
Example: SPD 250480D2J = SPD Series, 250kA Per Phase, 480D Voltage, Standard Feature Package, Motor Control Center Application.
SPD 250 480D 2 J
SPD
kA Rating
Options
50kA Per Phase
80kA Per Phase
100kA Per Phase
120kA Per Phase**
160kA Per Phase**
200kA Per Phase**
250kA Per Phase
300kA Per Phase
400kA Per Phase
Feature Package
Options
1 = Basic.
Dual colored LED per Phase to indicate Protection status
Dual colored LED to indicate protection status of the N-G Mode on
units with a Neutral Wire
2 = Standard.
Dual colored LED Per Phase to indicate Protection Status
Dual colored LED to indicate Protection Status of the N-G Mode on
units with a Neutral Wire
Audible alarm with Silence button
Form 'C' Relay Contact. See Table 4 Specifications
EMI/RFI filtering Providing up to 50dB of Noise Attenuation from
10KHz to 100Mhz
3 = Standard With Surge Counter
Dual colored LED Per Phase to indicate Protection Status
Dual colored LED to indicate Protection Status of the N-G Mode on
units with a Neutral Wire
Audible alarm with Silence button
Form 'C' Relay Contact
EMI/RFI filtering Providing up to 50dB of Noise Attenuation from
10kHz to 100Mhz
Surge Counter with Reset Button
Application Suffix
Options
Integrated Units
A = Panelboards, Direct Bus Mounted
B = Switchgear (Includes remote display panel & mounting hardware). Order cable
separately
C = Panelboards, Switchboards, Busway
J = Motor Control Centers
NOTE: Units used in Panelboard applications are available in
50 – 200kA ratings only
NOTE: Use the 'C' option for Panelboard Applications when
unit is connected through a Circuit Breaker
Voltage Code
Options
Integrated Units
240S = 120/240 Split Phase
208Y = 120/208 Wye (4W + G)
220Y = 127/220 Wye (4W + G)
400Y = 230/400 Wye (4W + G)
480Y = 277/480 Wye (4W + G)**
600Y = 347/600 Wye (4W + G)
240D = 240 Delta (3W + G)
480D = 480 Delta (3W + G)**
600D = 600 Delta (3W + G)
240H = 240 Delta High Leg (4W + G) on 'B' Phase
230L = 230 Single Phase*
NOTE: Please consult the factory for 240 Delta HIgh
Leg (4W+G) applications with high leg on 'C' Phase
* UL1449 3rd edition only
6.0 Ordering Guidelines
Table 5. Eaton SPD Series
** Eaton’s Wye Catalog Numbers SPD120480Y2C, SPD160480Y2C, and SPD200480Y2C and Eaton’s Delta Catalog Numbers SPD120480D2C, SPD160480D2C, and SPD200480D2C
meet the requirements of IEC 61643-11/EN 61643-11, Part 11: Test Class II, and intended to be installed in indoor applications with a degree of protection rated IP 00.