A.7
PVE12
3 4 5 876 9 101 2 11 12 13
Model Code
1 Model series
PVE – Piston pump, variable, E series
2 Frame size
12 – 45 l/min (12 USgpm) @ 1800 rpm
25cm
3
/r (1.54 in
3
/r)
3 Rotation (viewed from shaft end)
R – Right hand
L – Left hand
4 Mounting flange
B – SAE “B” 2-bolt
5 Input shaft
1 – SAE “B” straight keyed
2 – SAE “B” splined
28 – 26 tooth splined (special Vickers).
See chart below
6 Port configuration
E – End ported, SAE O-ring ports
(standard)
M – End ported, metric O-ring ports per
ISO 6149 (optional)
7 Shaft seal
S – Single
8 Pump design
10 – 10 series
Subject to change. Installation
dimensions remain the same for design
numbers *0 to *9 inclusive.
9 Adjustable maximum volume stop
C – With stop option
Blank – Omit if not required
10 Control options
C** – Pressure compensator,
adjustable from 20–207
bar (300–3000 psi).
Standard setting “C21”
indicates 207 bar (3000
psi). (standard)
CG – Remote adjustment
pressure compensator
(optional)
C**VP11 – Load sensing with “C” type
pressure limiter. Load
sense set at 11 bar (160
psi). (standard)
C**VPC24 – Load sense with “C” type
pressure limiter. Load
sense set at 24 bar (350
psi). (optional)
** indicates pressure compensator
setting in tens of bar.
11 Control bleed down
(CVP models only)
B – Bleed down orifice (0.015” dia.)
in load sense control
(standard)
P – Plug, no bleed down orifice in
load sense control (optional)
Blank – Omit for C, CC, CD and CG
models
12 Control design
11 – CC, CG, and CCG
12 – CVP, CVPC, CCVP, and CCVPC
13 Special suffix
Blank – Omit if not required
298 – Special CG control for use with
electronically modulated relief
valve
PVE12 Shaft Torque Data
Input Shaft Designation Thru–Drive Option Maximum Input Torque N.m (lb.in.)
1 SAE “B” straight keyed No 135 (1200)
2 SAE “B” spline 13T, 16/32 D.P., FRMDF No 208 (1850)
28
Special Vickers 26T for use in rear pump of
tandem PVE**-PVE12 unit
No N/A