Eaton PVE21 User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
A.6
Overspeed Limits
At Full Flow Conditions
Displacement cm
3
/r (in
3
/r)
Inlet
Pressure/Vacuum*
Maximum Speed**
rpm
5 psig 2800
PVE21 full displacement 45 (2.75)
0 psig
2400
PVE19 full displacement 41 (2.50)
5 in. Hg.
2100
5 psig 3100
PVE19/21 destroked 33 (2.00)
0 psig
2750
PVE19/21 destroked 33 (2.00)
5 in. Hg.
2500
5 psig 3200
PVE19/21 destroked 25 (1.50)
0 psig
3000
PVE19/21 destroked 25 (1.50)
5 in. Hg. 2850
PVE12 limited to 3000 rpm at full displacement and 0 psig inlet.
* Minimum pressure/vacuum required at pump inlet to operate at displacement and speed listed.
** Speeds not listed, but within displacements shown above, may be calculated from values listed.
At Load Sense Standby Condition CVP(C) Controls
Pump must be in zero flow, low pressure, standby condition when operated at listed
speed. Pump may be damaged if not slowed to normal rated speed before being
operated at full flow.
Model Code
Maximum Speed
rpm
PVE12 3600
PVE19 3200
PVE21 3200
Response Data
Yoke response recorded at rated speed and pressure, 0 psi inlet, 82C (180F), SAE 10W oil. Pressure rise was 6900 bar
(100,000 psi) per second.
PVE12 PVE19/21
Control Type
On Stroke sec.
Off Stroke sec. On Stroke sec. Off Stroke sec.
Pressure compensator 0.030 0.012 0.050 0.025
Load sense compensator 0.040 0.012 0.060 0.020
Sound Data
Sound level dB(A) per ISO 4412 standard.
1200 rpm, 70 bar (1000 psi) 1500 rpm, 140 bar (2000 psi) 1800 rpm, 207 bar (3000 psi)
Model Code
Full Stroke
dB(A)
Compensated
Stroke dB(A)
Full Stroke
dB(A)
Compensated
Stroke dB(A)
Full Stroke
dB(A)
Compensated
Stroke dB(A)
PVE12 71 65 76 72 77 77
PVE19 79 74 83 85 86 87
PVE21 75 73 79 81 83 83
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 27 28

Comments to this Manuals

No comments