A.5
Operating Data
Displacement, Speed, and
Pressure Ratings
Displacement cm
3
/r (in
3
/r)
Rated Input
Maximum Pressure bar (psi)
Model Code
Shaft End Pump
Cover End Pump
Speed
(At 0 psig Inlet)
Shaft End
Cover End
PVE12 25 (1.54) 3000 207 (3000)
PVE19 41 (2.50) 2400 207 (3000)
PVE21 45 (2.75) 2400 186 (2700)
PVE41-25V40M (mobile) 41 (2.50) 40 (2.44) 2400 207 (3000) 207 (3000)
PVE41-25V45M (mobile) 41 (2.50) 45 (2.75) 2400 207 (3000) 207 (3000)
PVE41-25V55M (mobile) 41 (2.50) 55 (3.36) 2400 207 (3000) 207 (3000)
PVE41-25V67M (mobile) 41 (2.50) 67 (4.09) 2400 207 (3000) 207 (3000)
PVE45-25V40M (mobile) 45 (2.75) 40 (2.44) 2400 186 (2700) 207 (3000)
PVE45-25V45M (mobile) 45 (2.75) 45 (2.75) 2400 186 (2700) 207 (3000)
PVE45-25V55M (mobile) 45 (2.75) 55 (3.36) 2400 186 (2700) 207 (3000)
PVE45-25V67M (mobile) 45 (2.75) 67 (4.09) 2400 186 (2700) 207 (3000)
PVE41-25V40I (quieted) 41 (2.50) 40 (2.44) 1800 207 (3000) 172 (2500)
PVE41-25V45I (quieted) 41 (2.50) 45 (2.75) 1800 207 (3000) 172 (2500)
PVE41-25V55I (quieted) 41 (2.50) 55 (3.36) 1800 207 (3000) 172 (2500)
PVE41-25V67I (quieted) 41 (2.50) 67 (4.09) 1800 207 (3000) 172 (2500)
Pressure Limits*
Port Pressure Range
Inlet 0,2 bar to 2,0 bar (5 in. Hg. vacuum to 30 psi)
Outlet See Maximum Pressures listed above
Drain 0,35 bar (5 psig) maximum
* Integral relief valve protects pump by limiting case pressure peaks to 0,7 bar (10 psi) above
inlet pressure. Flow from valve returned directly to pump inlet. Case drain line required to
limit steady-state case pressure.
See page A.6 for Inlet vs. Speed details.
Preparation for Start-up
Before starting a PVE pump, fill the case
through the uppermost drain port with
system hydraulic fluid. The case drain
line must be connected to the reservoir
below oil level. For multiple pump
arrangements that include non-PVE
sections, the requirements of the
non-PVE units must also be considered.
Mounting
Vickers Engineering recommends these
PVE series piston pumps be mounted
horizontally.