Eaton Powerware 9355 Parallel Installation Guide

Browse online or download Installation Guide for Uninterruptible power supplies (UPSs) Eaton Powerware 9355 Parallel. Eaton Powerware 9355 Parallel Installation guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Installation Guide

Powerware SeriesEaton 9355 Tie CabinetInstallation GuideFor use with Eaton® 9355 20/30 kVA UPSs®

Page 2

SAFETY WARNINGSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality4Consignes de SécuritéCONSIGNES DE

Page 3 - Class A EMC Statements

SAFETY WARNINGSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality5Advertencias de SeguridadINSTRUCCI

Page 4 - Special Symbols

SAFETY WARNINGSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality6

Page 5 - Table of Contents

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality7Chapter 3 Tie Cabinet InstallationThe Eaton 9355

Page 6 - TABLE OF CONTENTS

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality85. Remove the Tie Cabinet

Page 7 - Chapter 1 Introduction

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality97. Punch holes for the co

Page 8 - INTRODUCTION

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1010. From each UPS, remov

Page 9 - Chapter 2 Safety Warnings

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1118. Hardwire the UPS inp

Page 10 - CONSERVER CES INSTRUCTIONS

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality12Jumpers(remove threewire

Page 11 - GUARDE ESTAS INSTRUCCIONES

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1319. Hardwire the output

Page 12 - SAFETY WARNINGS

Eaton, Powerware, LanSafe, Powerware Hot Sync, and X-Slot are registered trademarks of Eaton Corporation or its subsidiaries and affiliates.Greenlee i

Page 13 - W A R N I N G

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1421. Hardwire the load to

Page 14 - Figure 3. Internal Covers

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1522. Wire the maintenance

Page 15 - punch or similar device

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1625. Wire the AC input to

Page 16 - Figure 5. UPS Front View

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality17Figure 11. Parallel UPS

Page 17 - TIE CABINET INSTALLATION

TIE CABINET INSTALLATIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality18

Page 18

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality19Chapter 4 Installing OptionsThis section describ

Page 19

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality20To install the Powerware Hot S

Page 20 - Figure 8. Load Connections

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality214. Set the jumper pins on the

Page 21

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality228. Route the wiring through th

Page 22 - Line 1 Line 2 Line 3

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality2310. Route the pull-chain wirin

Page 23

Class A EMC StatementsFCC Part 15NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to pa

Page 24

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality2411. Wire the pull-chain wiring

Page 25 - Chapter 4 Installing Options

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality25ALARM 1ALARM 2BPO RS232 RELAY

Page 26 - Wiring Access Plate

INSTALLING OPTIONSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality26

Page 27 - Jumper J7 - Pins 2 and 3

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality27Chapter 5 Service and SupportIf you have any que

Page 28 - INSTALLING OPTIONS

SERVICE AND SUPPORTEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality28

Page 29

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality29Chapter 6 WarrantyLimited Factory WarrantyThree‐

Page 30 - C A U T I O N

WARRANTYEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality30COSTS NOT RELATED TO WARRANTY: The End-

Page 34 - SERVICE AND SUPPORT

Special SymbolsThe following are examples of symbols used on the UPS or accessories to alert you to important information:RISK OF ELECTRIC SHOCK - Obs

Page 35 - Chapter 6 Warranty

*164201630B*164201630 B

Page 36

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerqualityiTable of Contents1 Introduction 1 . . . . . . . .

Page 37

TABLE OF CONTENTSEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerqualityii

Page 38

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality1Chapter 1 IntroductionA Tie Cabinet can be instal

Page 39

INTRODUCTIONEaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality2

Page 40 - *164201630B*

Eaton 9355 Tie Cabinet (20/30 kVA) Installation Guide S 164201630 Rev B www.eaton.com/powerquality3Chapter 2 Safety WarningsIMPORTANT SAFETY INSTRUC