Metering Devices, Protective Relays, Software and Connectivity
Protective Relays
DP-300
Contents
Description Page
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . V3-T9-158
FP-6000 Feeder Protection. . . . . . . . . . . . . . . . . . . V3-T9-162
FP-5000 Feeder Protection. . . . . . . . . . . . . . . . . . . V3-T9-172
FP-4000 Feeder Protection. . . . . . . . . . . . . . . . . . . V3-T9-180
MP-3000 Motor Protection. . . . . . . . . . . . . . . . . . . V3-T9-188
MP-4000 Motor Protection. . . . . . . . . . . . . . . . . . . V3-T9-198
MD-3000 Motor/Generator Differential Relay. . . . . V3-T9-204
Digitrip 3000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-207
VR-300 Multifunctional Voltage Relay . . . . . . . . . . V3-T9-217
DP-300 Current Differential Protection Relay
Standards and Certifications . . . . . . . . . . . . . . . V3-T9-222
Technical Data and Specifications . . . . . . . . . . . V3-T9-222
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-224
EDR-3000 Feeder Protection . . . . . . . . . . . . . . . . . V3-T9-226
ETR-4000 Transformer Protection Relay. . . . . . . . . V3-T9-237
Ground Fault Relay . . . . . . . . . . . . . . . . . . . . . . . . . V3-T9-250
Universal RTD Module . . . . . . . . . . . . . . . . . . . . . . V3-T9-254
IQ 125 Volt DC Power Supply . . . . . . . . . . . . . . . . . V3-T9-258
DP-300 Current Differential Protection Relay
Product Description
The current flowing in the
individual conductors is
measured by means of
current transformers
installed on both sides of
the protection zone. These
transformers form the limits
of the protection zone. By
means of freely configurable
relays, the unit will indicate
if any of the adjusted fault
current limits have been
exceeded. The unit counts
with a slope characteristic
to prevent operation due
to CT ratio mismatches,
CT ratio errors, CT saturation
and errors because of tap
changes.
For transformer applications,
the unit has 2nd and 5th
harmonic restraints to
prevent misoperation in case
of inrush currents caused
for energization or over
excitation of the transformer.
When used in transformer
applications, the DP-300
allows you to change the
phase shift of the
transformer, without having
to worry about changing the
connection of the external
CTs, via selecting the vector
group in the display. The
different nominal currents of
the high and low voltage side
of the transformer, as well as
the transformer ratio, may be
configured. Every measuring
point may be set separately.
These features permit the
DP-300 to be universal in its
applications.
The DP-300 permits design
simplification of the
switchgear cabinet, facilitates
the commissioning, ensures
the operation of the system,
is user friendly and increases
the availability of the system.
Application Description
The DP-300 offers a three-
phase current differential
protection for generators,
motors and two winding
transformers, see Page V3-
T9-223.
Features, Benefits
and Functions
True rms 6 x current
measurement, three-phase
system on both sides of
the protected zone
Secondary current
transformer output
available as: /1A or /5A
Configurable trip set
points for:
Differential current (Id)
Restrain current (Is)
Configurable delays
Four alarm relays
Three discrete inputs (for
blocking, acknowledgment
and configuration)
Two-line LC display
Configurable transformer
ratio
Configurable vector group
Transformer inrush
detection/suppression
Individual configuration of
the nominal current for the
high- and low-voltage side
of the transformer
Configurable transformer
ratio separated for currents
of high- and low-voltage
side of the transformer