EATON Vickers ‘E’ Series Piston Pumps V-PUPI-TM010-E December 2009 14
1, 2
Pump Series
PV –
Open Circuit Piston
Pump
3,4,5,6
Displacement
E19A –
41.0cm
3
/r (2.50 in
3
/r)
E21A – 45.1cm
3
/r (2.75 in
3
/r)
7
Input Shaft Rotation
R
Right-Hand Rotation
(cw)
L Left-Hand Rotation
(ccw)
8, 9
Front Mounting and
Input Shaft
01
SAE B 2 bolt, Keyed
02 SAE B-B 2 bolt, Keyed
04 SAE B 2 bolt, tapered
05 SAE B 2 bolt, splined
13t 16/32DP long
shaft
08 SAE B-B 2 bolt,
splined 15t 16/32DP
09 SAE B 2 bolt, splined
26t 32/64DP
10,11
Main Ports Location
and Size
AA
Side ports, SAE
o-ring; #24 suction,
#14 pressure
AB End ports, SAE o-ring;
#24 suction, #14
pressure
AC Side ports, SAE 4 bolt
flange, Code 61;
1 1/2” suction,
1” pressure
AD End ports, SAE 4 bolt
flange, Code 61;
1 1/2” suction,
1” pressure
AE Side ports, ISO 6149-
1; M48 suction, M33
pressure
AF End ports, ISO 6149-
1; M48 suction, M33
pressure
AS End ports ISO 6162
4 bolt flange; 1 1/2”
suction, 1” pressure
12
Drain Port Size and
Location
01
#10 SAE O-ring port
top (D1)
02 #10 SAE O-ring port
bottom (D2)
06 M18 metric O-ring
port – top (D1)
07 M18 metric O-ring
port – bottom (D2)
13
Diagnostic Pressure
Port
0 – No diagnostic pressure
port
1 #4 SAE O-ring port
plugged
2 M14 metric O-ring port
– plugged
14
Controller Type
A –
Pressure Compensator
B – Pressure and flow
compensator
C
Electric dual range
pressure compensator
with directional control
valve
D Hydraulic remote con-
trol pressure compen-
sator
E Unloading valve
(accumulator circuits)
F Electric dual range
pressure compensator
without directional
control valve
15,16
Pressure Comp./Un-
loading Valve Setting
00
No pressure
compensator setting
18 182.7-189.6 bar
(2650-2750 psi)
33 206.8-213.7 bar
(3000-3100 psi)
17,18
Flow Comp. Setting
or Unload Valve
00
No pressure
compensator setting
11 9.65-12.41 bar
(140-180 psi)
14 12.41-15.17 bar
(180-220 psi)
24 22.75-25.51 bar
(330-370 psi)
19,20
Secondary Compen-
sator Setting
00
No secondary com-
pensator setting
04 186.2-193.1 bar
(2700-2800 psi)
21
Control Special Features
0 – No Special Features
A – Bleed down orifice
B – External load-sensing
adjustment
G – High rate spring for low
pressure setting
J
Bleed down orifice and
high rate spring for low
pressure setting
PV E19A R 01 AA 1 0 B 33 24 0 0 A 1 AA 1 AF CD 0 A
7 12 2113 14 2522 30 31
1, 2 3,4,5,6
8,9
10,11 15,16 17, 18 19,20 23, 24 26, 27 28, 29
Model Code