EATON Vickers ‘E’ Series Piston Pumps V-PUPI-TM010-E December 2009 11
Controls
PVE012
See installation dimensions
page 10 for other details.
52,0
(2.05)
72,6
(2.86)
90,1
(3.55)
63,8
(2.51)
28,4
( 1.12)
123,8
(4.87)
30,0
(1.18)
250,1
(9.85)
218,2
(8.59)
194,2
(7.65)
11,8
(0.43)
max.
Maximum stop
adjusting rod
(Approx. 2,22 cc/rev
change per turn)
Compensator position
for R.H. rotation
Compensator position
for L.H. rotation
214,3
(8.44)
28,4
( 1.12)
19,0
(0.75)
52,0
(2.05)
128,3
(5.05)
70,6
(2.78)
191,0
(7.52)
Load sensing
compensator
control port location
for L.H. rotation
Compensator
position for
R.H. rotation
Load sensing compensator control
port location for R.H. rotation
.4375-20 UNF-2B thd. SAE O-ring
boss connection .250 O.D. tubing
68,3
(2.69)
10,6
(0.42)
Compensator
position for
L.H. rotation
Locknut
11,2
(0.44)
across flats
Adjustment
Loosen the locknut on the
adjusting rod. Turn the
adjusting rod clockwise to
decrease maximum pump
delivery, or counterclock-
wise to increase maximum
pump delivery, until the
desired setting is obtained.
Secure the setting by tight-
ening the locknut. To assist
initial priming, the manual
adjustment control setting
must be at least 40% of
the maximum flow posi-
tion.
This control enables maxi-
mum pump delivery to be
externally adjusted from
25% to 100% while main-
taining all the standard
features of a pressure com-
pensated pump.