EATON CORPORATION POWERWARE 9315 UPS PRODUCT FOCUS
6
Y
TEM
MAINTENAN
CE
BYPA
SS
(
OPTIONAL
)
MI
S
MBP
C
RITI
C
AL L
O
A
D
MO
DULE 4
MO
DULE 5
MO
DULE 6
MO
DULE 7
MO
DULE 8
CB
S
C
B
P
FBP
S
Y
S
TEM
BYPA
SS
M
O
DUL
E
MO
DULE 1
MO
DULE 2
MO
DULE
3
Powerware Hot Sync – Capacity /Redundant
(200 - 750 kVA Modules)
Tie Cabinet
Source
A
Optional Source B Optional Source
C
Critical Load
MOB 2MOB 1
Module 1
Battery 1 Battery 2
Module 2
Powerware Hot Sync – Redundant
(200 - 500 kVA Modules)
Powerware Hot Sync–Redundant
This multi-module system provides unmatched system reliability
and availability. This configuration allows full maintenance on any
module without need for an external maintenance bypass and with-
out having to remove the critical load from conditioned power. No
other UPS manufacturer can provide this capability.
Powerware Hot Sync–Redundant with Capacity
This system topology can accommodate up to eight modules in par-
allel for your larger and most critical applications. Superior moni-
toring and highly automated controls make this system as easy to
operate as a single module system.
You may not require this level of reliability now, if you are just pur-
chasing a single UPS module. However, after the purchase you can
effortlessly expand from a single module system to a two-module
Powerware Hot Sync redundant system and on to
an eight-module Powerware Hot Sync capacity system. Isn’t it reas-
suring to know that the Powerware 9315 provides this degree of
scalability – if you need it?
Powerware Hot Sync
TM
Technology
Today, your critical loads demand even greater protection. That’s
why we developed a unique paralleling system that provides
redundancy and capacity capability with high 9’s system avail-
ability.
While you may be familiar with paralleling, the patented
Powerware Hot Sync’s technology eliminates more risks to your
system. Typically, in order for modules to operate in parallel as a
system, they must communicate with each other through intricate
wiring to coordinate the primary paralleling operations of output
synchronization, load sharing and selective tripping of a module.
But this traditional method of communication introduces a sys-
tem-level single point-of-failure. If this communication link goes
down, so does your critical load. And that’s a risk you just can’t
afford to take.
Instead, Powerware Hot Sync technology eliminates the need for
the modules to communicate with each other. Each UPS module
has the ability to synchronize and support the critical load inde-
pendent of the other modules. This unique approach to parallel-
ing completely eliminates the traditional single point-of-failure.
With the world teeming with technology that must run 24x7, 365 days a year, it’s no surprise that power
protection has been elevated from a dusty corner in the basement to an integral and sophisticated part of
an organization’s overall technology infrastructure. The Powerware 9315 offers a variety of power systems
designed to integrate with your technology and meet your availability requirements.
Powerware Solutions for Redundancy and Additional Capacity